    Hydraulic system contamination

    Hydraulic system contamination

    Share this post

    Hydraulic system contamination is responsible for 80% of system failures – whether through the introduction of contaminated fluid or more progressively through, for example, metal surface wear, corrosion or cavitation.

    Contamination can be caused by either the presence of solids, other liquids or gases in the hydraulic fluid. In this article, produced in conjunction with MP Filtri, we look at the effects of each, best practice for prevention and how best to remove contaminants already in your system.

    Liquid Contamination

    This can include the presence of water due to condensation or external infiltration or acids. Water is a chemical contaminant in oils; at 100% relative humidity water forms as bubbles in hydraulic systems. The effects can be dangerous if water is present and is not monitored and controlled properly.

    How water affects your system

    When free water exists in an oil, the bubbles it forms can interfere with particle counts and affect system performance and outputs. Excess water will typically also give a ‘dirtier’ reading than the actual system cleanliness – oil may turn cloudy or opaque which may mean that the oil should be replaced. To extend systems life, oil should therefore always remain relatively translucent.

    Poor water monitoring and control can lead to: shorter component life; wire erosion and vaporous cavitation; hydrogen embrittlement; oxidation and component wear. All of these can exist depending on individual system designs and have the potential to lead to catastrophic failure.

    MP Filtri recommend that you set a maximum alarm setting for water content in your oil, and where possible aim to operate well within this limit so that water never becomes a problem. Their water sensor options can monitor levels of water in your hydraulic oil allowing you to keep your system in good condition.

    Removing the risk of water-induced failures

    To remove the risk of water induced failures, hydraulic system contamination management and operator training should cover:

    • Oil management and handling
    • Using breathers or tank headspace protection
    • Wwashing down of systems and protection during this operation
    • System equipment IP ratings and susceptibility to moisture ingress
    • Formation of condensate on the surrounding area
    • Secondary sealing for critical applications
    • Storage of oil drums
    • Periodic draining of particularly susceptible systems

    How can I prevent water from getting into the system?

    Hydraulic fluids should always be kept in sealed containers stored in relatively dry environments until needed. Lids should be checked routinely and tightly secured. Moisture from rainfall or humidity, can cause water ingress into the container. As some fluids are hygroscopic, meaning they absorb moisture, always use lids on tanks and, if necessary, use a hygroscopic breather to further reduce the risk of moisture entering your system.

    De-humidifiers can be quite effective at removing entrained water, but good quality controls and working practises are the real key to eliminating water completely. Always consider the working environment: try and reduce large temperature fluctuations and be mindful of the weather outside, especially the dew point temperature.

    Gaseous Hydraulic System Contamination

    Gaseous hydraulic system contamination can be caused by air entering the system perhaps through an inadequate oil level in the tank, drainage in suction ducts, or incorrect sizing of tubes or tanks. You can evaluate how much air is in your system by measuring the reservoir level pressurized and then un-pressurized. If the fluid level in the tank is lower when pressurised, this could indicate that air is present in the system – some maintenance may be required.

    Aerated fluid can cause a variety of problems with differing implications for performance, maintenance costs and safety. These include:

    • Increased fluid temperatures
    • Reduced lubricity
    • Cavitation and system component erosion
    • Noise
    • Dampening and poor system control
    The sensitivity of automatic particle counters operating on the light extinction principle can also be affected when air is entrained in a system.

    How can I limit the amount of air getting into my system?

    When measuring particulate contaminants, steps should be taken to ensure that the product is not exposed to aerated fluid. The following factors should be considered to avoid aerated fluid in new and existing installations:

    • Significant or sudden pressure drop
    • Hydraulic shock resulting from sudden operation of valves and pumps
    • Inadequate operating conditions for different types of pump
    • Inadequate diffusion of the fluid at the return tank
    Extra care should also be taken when replacing system components. Where necessary and/or possible, components should be pre-filled with new, filtered oil before installation. This will reduce the amount of air being placed into the system.

     

    How can I remove air already in my system?

    There are a number of ways to remove air from a system, but the following are probably the most simple and commonly used:

    • Reservoir air bleed valves
    • Baffled Reservoir tanks
    • System maintenance procedures
    • Adequate diffusion back to tank
    • Reservoir level
    Reservoir bleed valves are good, but, as their name suggests, their use is limited to the reservoir only. They may not detect air in other parts of the system. It is certainly good practice to use these devices on closed systems. Baffles are often used on systems with open tanks to allow any air to naturally diffuse into the surrounding atmosphere. It is vital to keep tank levels high enough so that the baffles can be effective. When returning back to tank, it is also important to ensure that the flow is diffused to avoid a sudden and violent discharge as this can drag air into the system. , Try to keep the flow rate back to the tank low, and discharge the fluid towards the surface of the tank to encourage its escape.

    Solid Contaminants

    Solid contamination can be caused by many factors including rust, metal particles, slag, fibres, silica, dirt or dust, rubber particles, paint particles, silt, bacteria or additives. Examining the type of contaminant may help to identify where and how it is entering the system. Understanding this may then enabling preventative actions to be taken.

    Good work practices are essential to avoid this type of hydraulic system contamination and include the following:

    • No food and drink nearby
    • Pre-filter your oil before placing into or returning back to the tank
    • Use a dedicated funnel for a particular type of fluid when pouring into the tank
    • Have a dedicated fill point for the reservoir
    • Use a sloped or conical tank design with an outlet at the bottom, so that contaminants are captured by the first bank of filters
    • After filling or topping up with new oil, let the system flow and filter, reaching a natural equilibrium point before using live in your process

    What effect does solid contamination have on my system?

    Contamination can result in mechanical wear and place excessive stress on system components, such as pumps and valves. It can also cause corrosion, lead to a loss of protective coatings on components and clog orifices, nozzles, and jets. Operating temperatures can increase and fluid compressibility can change.

    One of the main areas of degradation is the formation of oxygenated & heavy polymeric compounds. These compounds are often in-soluble and settle out of the fluid as a gel or sludge. These compounds form more quickly in the presence of water and metal – care should be taken to remove these types of contaminant from your oil.

    When a fluid is contaminated its viscosity will normally increase, leading to higher than normal friction and subsequent temperature increases. This can reduce system efficiency, wear components and affect compression rates. Contamination can also lead to catastrophic failure.

    What factors can affect particle distribution and concentration with my system?

    A hydraulic systems’ construction is mainly metal or elastomer/textile-based. Over time, and in reaction to changing fluid conditions such as temperature, pressure and chemical decomposition, these materials can become susceptible to corrosion and leach out contaminants into the system.

    As a system operates, contamination is generated and needs to be controlled. It is physically impossible to achieve 100% efficiency in any given system; some particles will always get through filtration. It is generally assumed that the fluid is “clean” downstream of any filtering and purification, although this may not be the case.

    Homogeneity is important in accurately assessing system contamination: a homogenous solution is uniform in its composition and particles are evenly distributed within it. The majority of real world systems are heterogeneous (un-evenly composed) and when taking measurements this must be considered as a significant variable between tests.

    Viscosity, temperature, electrical conductivity, surface tension are some of the factors that can adversely affect the overall quality of your fluid.